Avaya 03-300430 User Manual
AN-LN-PT (Analog Line Port)
Issue 1 June 2005
441
1008
ABRT
A ringing circuit could not be allocated. Either every ringing circuit is
active, the ringing generator is defective, or it is incorrectly wired.
active, the ringing generator is defective, or it is incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error
Log.
3. If ABORT 1008 occurs for this test on other circuit packs as well, the
ringing generator may be defective or is incorrectly wired (see
4. If an ABORT 1008 does not occur on other ports, then all four ring
phases are active.
1018
ABRT
Administration has disabled the test. The default for the Test field on the
station screen is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test 48, which can be
disturbing to customer or terminal equipment).
station screen is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test 48, which can be
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Enter y in the Test field.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 130: Test #48 Station Present Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation