Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
462 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1. When attempting to record an announcement, users hear the proper record tone, but the 
announcement does not record (they do not know it until the announcement is played 
back).
2. Performing a test board long when the circuit pack is in this state yields the 
following abort codes:
Ports 1 AND 9 abort Test #206 with code 1024
Ports 1 AND 9 abort Test #205 with code 2000
Board level Tests #209 and #210 abort with code 1024
3. Save/restore announcements times out with Error encountered, can’t complete 
request 
The Announcement circuit pack lock-up can be cleared remotely by performing a soft reset 
to the circuit pack:
busyout board PCSS (this command drops all calls in progress on the Announcement 
circuit pack)
Reset circuit pack using reset board PCSS
Release circuit pack using release board PCSS
Super frame match inquiry test (#211)
The super frame is a means by which the SP synchronizes with the 140AY device on the 
Announcement circuit pack. If the super frame is not synchronized, the SP is not able to 
properly process record/playback requests. Both the SP and the hardware generate a super 
frame pulse. When these two pulses are out of synch, the SP sets a flag to indicate the 
mismatch. When this test is run, the state of this flag is returned.
Table 137: TEST #211 super frame match inquiry
Error
code
Test
result
Description/ Recommendation
2000
ABRT
Response to the test request was not received within the allowable time 
period. If Error Type 1538 is present in the Error Log, follow the maintenance 
strategy recommended for this Error Type.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2