Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
530 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
B-side ATM-EI—Critical Reliability
1. Enter status pnc, and ensure that the A-PNC is active.
If not, request a pnc interchange using reset pnc interchange.
2. Enter busyout pnc-standby.
3. Enter list config carrier, and verify that an ATM circuit pack is assigned for the new 
location.  If not, add the ATM circuit pack’s translations.
4. Enter busyout atm pnc n (connection number) b-pnc.
5. Enter change atm pnc n (connection number) and change circuit pack location for the B 
side.
6. Enter release pnc-standby.
Changing ATM Address of Standby
ATM PNC EI, Critical Reliability
1. Enter busy pnc-standby.
2. Enter change atm pnc n (connection number), and change the ATM address for the 
standby side.
3. Enter release pnc-standby.
Error Log Entries and Test to Clear Values
Table 169: ATM-EI Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test board location
2 (
)
None
MIN
ON
0
busyout board 
location
WRN
OFF
release board location
)
0
None
WRN
OFF
)
None
MIN
ON
)
None
MIN
ON
257-259 
(
Any
Expansion Interface 
Control Channel test 
(#316)
MAJ
ON
test board location r 2
 1 of 3