Avaya 03-300430 User Manual

Page of 2574
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005
549
 
10MM
FAIL
The failure codes only apply to a system equipped with an ATM Switch.  
The letters “MM” refer to the distant or far-end PN, and “NN” to the 
near-end ATM-EI under test.
The test tone was detected correctly in forward direction (data sent from 
the PN where the circuit pack under test resides and detected correctly in 
port network MM), but not the opposite direction.
1. Test the active Tone-Clocks on the “MM” PN and the PN where the 
ATM-EI under test resides (test tone-clock location).  This 
determines if a dial tone is supplied.
2. Ensure that the ATM address of the ATM-EI circuit pack under test 
matches the ATM address on the ATM switch for the port to which this 
circuit pack is connected.  Refer to ATM Installation, Upgrades, and 
Administration using Avaya Communication Manager, 555-233-124,
 
for the procedure to check the ATM port address on the ATM switch.
3. Run Test #241 on the active ATM-EI in port network MM.  If this test 
fails with Error Code 10NN or 30NN, go back to step 2.
4. If the address was the same, replace the active ATM-EI circuit pack on 
port network MM.
5. If this test fails with Error Code 20NN or 40NN, replace ATM-EI circuit 
pack that had the initial problem.
Table 174: Expansion Interface 2-Way Transmission Test (#241)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 5 of 8