Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
726 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1141
ABRT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance 
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
1187
ABRT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, 
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, use release 
station to release the station.
b. If this error type is present for BRI-PORT and BRI-SET, use 
release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, use  
release port location to release the circuit pack, and run the 
test again.
If the error is present for BRI-SET only, use release port 
location
 to release the circuit pack, and run the test again. 
If the error is present for both BRI-BD and BRI-PORT, use  release 
board location 
to release the circuit pack, and run the test 
again.
Note:
Note:
When you release the circuit pack, you release every port 
associated with it.  If ports still need to be busied out, use 
busyout port location.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012
ABRT
Internal system error.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 245: Test #628 BRI XID  (continued)
Error 
Code
Test 
Result
Description / Recommendation