Communication Manager Maintenance-Object Repair Procedures
822 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1000
ABRT
System resources required to run this test were not available.  The port 
may be busy with a valid call.
1. Use display port location to determine the trunk group/member 
number of the port.  Use status trunk to determine the service state 
of the port.  If the port is active, wait until it is idle before testing.
2. If the port status is active but the port is idle (no calls), check the error 
log for error type 1025 (see the error log table for a description of this 
error and required actions).  The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
1001
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test.  The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.  Use status health to determine whether the 
system is experiencing heavy traffic.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test.  The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Enter list measurements tone-receiver to see information 
about the system’s tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/member 
number of the port.  Use status trunk to determine the service state 
of the port.  If the port is active, wait until it is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
Table 282: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation