Avaya 03-300430 User Manual

Page of 2574
CO-TRK (Analog CO Trunk)
Issue 1 June 2005
853
 
1002
ABRT
The system could not allocate time slots for the test.  The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test.  The system 
may be oversized for the number of Tone Detectors present, or some 
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
System resources required to run this test are not available.  The port may 
be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port.  Use status trunk to determine the 
service state of the port.  If the port is active, wait until it is idle before 
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
1018
ABRT
The test was disabled by administration.  Verify that the Maintenance 
Test field on the Trunk Group screen is set to n. To enable the test, use 
change trunk-group <x>, where <x> equals the number of the trunk 
group to be tested.  Change the Maintenance Test field on the screen to 
y.
1. Retry the command at 1-minute intervals up to 5 times.
S8300
 /
G700
  
1412
ABRT
This test does not execute on a G700 media gateway.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 291: Test #33 Looparound and Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4