Avaya 03-300430 User Manual

Page of 2574
DAT-LINE (Data Line Port)
Issue 1 June 2005
875
 
Audit Update Test (#36)
This audit verifies that the hardware state of the data line is consistent with the system 
translations. The audit queries the port for the switchhook state, the software state is updated 
according to the returned value. Also, the audit data line options down to the port.
Table 299: Test #36 Audit Update Test 
Error 
Code
Test 
Result
Description / Recommendation
1000
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate the problem if the test continues to abort.
1006
ABRT
An existing Error Type #769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for Error Type 
#769.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
ABRT
Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
7
FAIL
Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
PASS
The hardware port state is consistent with the software state. Investigate 
user-reported troubles on this port using other port tests and examining the 