Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-11
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing a power supply unit
Step 11
Power up the server. Refer to the 
Step 12
Test that the CD-ROM drive is correctly installed. See the 
for more information.
Replacing a power supply unit
This section describes how to replace a power supply unit. The power supply unit consists of the power 
supply and the power supply’s fan. This power supply unit is considered one single FRU. These 
components should not be removed or replaced separately. The only exception is that the power supply 
unit fan filter can be removed separately. See 
 for more information on the power supply unit fan filter.
Removing an old power supply unit
Note
The 8112 server has three power supply units. You can remove any one of the power supply units without 
shutting down the server or affecting performance.
To replace two or three power supply units at once, you must power down the 8112 server. Refer to the 
.
Step 1
Verify there is no user activity and back up the database. Refer to 
 and 
.
Step 2
Identify which power supply unit you are replacing. See 
.
Step 3
Using a screwdriver, loosen the two captive screws located at the bottom of the power supply sled to be 
removed. See 
Warning
Do not touch any of the exposed leads, terminals, or components. Hazardous voltages, capable of 
causing death, may be present in this product.