Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing the hot swap controller
Installing the new hot swap controller card
Step 1
Press the ejector levers outward. See 
.
Figure 5-19 Installing the Hot Swap Controller Card and Transition Module
Step 2
Holding the hot swap controller card by the ejector levers, partially insert the hot swap controller card 
into the slot, about half way.
Step 3
Verify that the hot swap controller card is properly seated in the guides on the top and bottom. If not, 
remove the hot swap controller card and try again.
Step 4
Pushing gently and firmly on the hot swap controller card’s face plate, slide the hot swap controller card 
into the slot until you encounter significant resistance. At this point, the ejector levers should be in 
contact with the chassis rails so they grab when pushed inward.
Step 5
Use the ejector levers to seat the hot swap controller card in the slot by closing the ejector levers toward 
one another until they are in the locked position. See 
Step 6
Secure the hot swap controller card by tightening the captive screws at the top and bottom of the panel. 
See 
.
Removing the old hot swap controller transition module
Step 1
Locate the hot swap controller transition module in slot 10 in the back of the server.
Step 2
Loosen the hot swap controller transition module’s two captive screws at the top and bottom of the panel. 
See Figure 5-18.