Cisco Headend System Release 2.7 Installation Guide

Page of 92
 
 
Install the NMI Software Remotely From the Alarm Manager Server 
78-745262-01Rev C
 
43 
 
9  Log in to the DNCS as dncs user. 
10  Type bin and then press Enter. The system enables binary transfer mode. 
11  Type hash and then press Enter. The system configures itself to display hash 
marks that show the progress as the NMI file transfers from the Alarm Manager 
server to the DNCS. 
12  Type cd  /export/home/stageNMI and then press Enter. The 
/export/home/stageNMI directory on the DNCS becomes the working 
directory. 
13  Type put  nmipackage.tar and then press Enter. The NMI software transfers 
from the Alarm Manager server to the DNCS. 
14  Type bye and then press Enter. The system closes the ftp session. 
15  Go to 
Extracting and Installing the NMI Software (on page 43). 
 
Extracting and Installing the NMI Software 
Now that you have transferred the NMI software from the Alarm Manager server to 
the DNCS, follow these instruction to extract the NMI software. 
Important:  The DNCS must be running when you install the NMI software. 
1  From an xterm window on the Alarm Manager server, type telnet  [IP address of 
the DNCS] and then press Enter. A telnet session opens on the DNCS. 
Note:  Substitute the IP address of the DNCS for [IP address of the DNCS]. 
2  Log in to the DNCS as root user. 
3  Type cd  /export/home/stageNMI and then press Enter. The 
/export/home/stageNMI directory on the DNCS becomes the working 
directory. 
4  Type ls  -l and then press Enter. The system lists the contents of the 
/export/home/stageNMI directory. 
Note:  The "l" character is a lowercase L. 
5  Does the output from the command in step 4 list the nmipackage.tar file? 
 
If yes, go to step 6; you successfully transferred the nmipackage.tar file. 
 
If no, something may have gone wrong when you tried to transfer the file 
from the Alarm Manager server to the DNCS. Follow these instructions. 
a  Type exit and then press Enter
b  Repeat the instructions in the previous procedure, Transferring the NMI 
Software From the Alarm Manager Server to the DNCS
6  Type tar  -xvf  nmipackage.tar and then press Enter. The system extracts the 
nmipackage.tar file.