Senstar Corporation E7BA0300 User Manual

Page of 16
WGS Configuration
Rev A
Page 10
FlexZone Wireless Gate Sensor
WGS Configuration
The Universal Configuration Module (UCM) is a Windows based software application, which 
serves as the calibration, setup and maintenance tool for the FlexZone sensor system and the 
Wireless Gate Sensor. The UCM communicates with the FlexZone processor locally through a 
USB connection, or remotely via the Silver Network Manager. The UCM communicates with the 
WGS through the FlexZone processor. When you start the UCM, a window displays that enables 
you to specify the device to which you are connecting.  
When the UCM connection is made, the FlexZone status window displays. Select the GSM Cfig 
tab to display the GSM configuration parameters. 
 shows the GSM Cfig window and the 
following table includes descriptions of the configuration settings. 
Note
Consult the online help for detailed information on UCM operation. 
Refer to the FlexZone Product Guide for additional information on 
configuring the FlexZone processor.
Tip
Save UCM files with a meaningful name, which includes the time and 
date. The files can then be reopened at a later time (Work Offline). 
Figure 12: Connecting the UCM (via USB)
Figure 13: Connecting the UCM (via TCP/IP
USB direct connection
in the Network Type: field select the network to 
which you are connecting (Silver for FlexZone)
in the Device Type: field select the device (FlexZone -4 or -60)
the address of the connected processor is displayed
select the connection type (i.e., USB) 
select the arrow to display the connected USB device
select the connect button to establish the connection
TCP/IP connection via Network Manager
in the Network Type: field select the network to which you
are connecting (Silver for FlexZone)
to connect via the Silver Network Manager, use the Browse 
button to locate the processor address OR use the Address 
field to specify the processor address (Browse requires a 
previously specified IP address and Network Manager ID)
select the connection type (i.e., TCP/IP)
enter the IP address of the Network Manager PC 
(if the NM and UCM are located on the same PC, 
enter 127.0.0.1 as the IP Address)
specify the ID number assigned to the Network Manager
select the connect button to establish the connection
in the Device Type: field select the device (FlexZone -4 or -60)