Digital Security Controls Ltd. 163G4005 User Manual

Page of 49
4005 Series
41
PTM
Check Dialing: disabled at factory default, if enabled, the missed dialing (i. e. when the PTM does not detect the number
dialed by the control panel on the PSTN line) will be count as failure by the “PTM function”.
PTM Max Errors Before Takeover: in this box, enter the total number of errors detected by the Communicator above which
the PTM function iactivated. The PTM function is disabled by default (the default setting is 0); set a value from 1 to 4 to ena-
ble the PTM function.
PTM All Numbers: all phone numbers, use the PTM function; the device will consider all numbers dialled as panel call.
Generic
Dialing Prefix: enter the Prefix for the numbers on the PSTN line.
The device will monitor the number dialled over external PSTN line and if the first digits of the dialled number matches with a pro-
grammed prefix (the default value is “9999”), the device shall switch the communication channel from PSTN line to simulated line
and routes the number dialled without the prefix over simulated line.
The switch prefix will be removed even in case of the number is dialled over simulated line.
Event Log
Events Log page is for reading and managing all Events stored.
The communicator can be stored up to 2048 events. Once the Log is full, each new event will overwrite and the oldest event will
be lost as a result.
The events will be stored by the Number of the event, date / time and type of event.
Icons on the bar of Event Log
 Clicking on the icon it is possible to upload new events on the Event Log.
 Clicking on the icon clears the selections of events in the Event Log.
 Clicking on the icon it is possible to export the events of the Log.
The communicator exports the file of the Log in the .csv format In the event of failure of Log exporting, the “unsuccessful log ex-
porting” event will be logged and the device will provide related signalling In the event of success, the communicator will provide
the signalling meaning “operations on USB stick are completed”
 Clicking on the icon to update the Event Log
Clicking on the field “All Events it is possible to set the temporal filters for selecting events for the Log:
All Events, TodayLast 7 daysLast 14 daysLast 30 daysLast year and Custom.