Digital Monitoring Products Inc PC0128 User Manual

Page of 31
Digital Monitoring Products
 
XT30/XT50 Installation Guide
20
COMPLIANCE
26.2  Call Waiting
The Call Waiting default setting is disabled. To cancel the Call Waiting feature, program * (star) 7 0 P
(pause), the standard telephone code prefix that cancels call waiting, into the telephone number string.
Cancel Call Waiting for telephone lines that have Call Waiting operational on the telephone line. See the
XT30/XT50 Programming Guide.
 
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent 
communication to the central station.
26.3  Entry Delay
Only use Entry Delay 1. Do not use Entry Delay 2. See the XT30/XT50 Programming Guide.
26.4  Local Bell
All non-fire zones such as Night, Day, Exit, Aux1 and Aux 2 must be programmed for local bell enabled with a
bell cutoff time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater. This does 
not apply to manually operated zone types such as Panic and Emergency.
26.5  Minimum Installation Requirements
SIA CP-01-2010 minimum system installation requirements include an XT30 or XT50, a local Bell, and off
premise DACT communication to an SCS-1R receiver plus one of the following compatible keypads. 
7060, 7063, 7070, 7073, 7160, 7163, 7170, or 7173 Thinline™ keypads 
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads 
7360 or 7363 Thinline™ Icon keypads 
7760 Clear Touch™ keypad 
7872 or 7873 Graphic Touchscreen Keypads