Digital Monitoring Products Inc PC0181 User Manual

Page of 58
XTLplus Installation and Programming Guide 
Digital Monitoring Products
21
DEVICE SETUP
25.3 
Device Name
This section allows you to define a 16 character alphanumeric name for the device 
number. If no name is entered, *UNUSED* is displayed.
To remove a keypad from the system, delete the device name by pressing any 
select key, then press the COMMAND key. The device name is now displayed as * 
UNUSED *.
25.4 
Wireless
Select YES to use a wireless keypad. Default is YES.
25.5 
Serial Number
Enter the eight-digit serial number found on the wireless keypad.
25.6 
Supervision Time
Press any top row key to select the supervision time required for the device. Press 
COMMAND to accept the default time. Default is 240 minutes.
Press the select key under the required number of minutes. The device must check 
in at least once during this time or a missing condition is indicated for that device. 
Zero (0) indicates an unsupervised wireless keypad.
Note: When the panel is reset, panel is powered down and powered up, or 
programming is complete, the supervision timer restarts for all wireless keypads.
Remote Options
26.1 
Remote Options
This section allows you to enter the information needed for Remote Command/
Remote Programming operation via Wi-Fi communication. A description of the 
Remote Options follows:
26.2 
Remote Key
This option allows you to enter a code of up to eight digits for use in verifying 
the authority of an alarm or service receiver to perform a remote command/
programming session. The receiver must give the correct key to the panel before 
being allowed access. All panels are shipped from the factory with the Remote Key 
preset as blank.
To enter a new Remote Key, press any select key and enter any combination of up 
to 8 digits. The numbers you enter appear as asterisks. 
Press COMMAND.
26.3 
Manufacturer Authorization
Enter YES to allow DMP service technicians to access the panel when required 
during system service or troubleshooting. This authorization automatically expires 
within one hour.
DMP remote service is provided on a read only basis: DMP technicians can look at 
the system programming and make suggestions only.
26.4 
Alarm Receiver Authorization
Enter YES to enable remote commands and programming to be accepted from the 
alarm SCS-1R Receiver. The Remote Key option can also be required.
When YES is selected, the panel requests the alarm receiver key during its first 
alarm communication with the first SCS-1R receiver. The panel retains this alarm 
receiver key in memory and allows remote commands to be accepted from the 
alarm receiver. If an alarm occurs during a remote connect, the alarm report is 
immediately sent to this receiver only.
When NO is selected, remote commands and programming are not accepted from 
the alarm SCS-1R receiver.
26.5 
Service Receiver Authorization
YES enables remote commands and programming to be accepted from a secondary 
service receiver other than the alarm SCS-1R Receiver. The Remote Key option can 
also be required.
With YES selected, the panel requests the service receiver key the first time it is 
contacted by the service receiver. The panel retains this service receiver key in 
memory and accepts remote commands from the service receiver.
* UNUSED *
WIRELESS? NO YES
 
SERIAL#: XXXXXXXX
 
SUPRVSN TIME: 240
 
SELECT MINUTES:
 0            60      240
REMOTE OPTIONS
REMOTE OPTIONS
RMT KEY:
MFG AUTH  NO YES
ALR RCVR  NO YES
SVC RCVR  NO  YES