SYSTEM OPTIONS
28.16 
Enable Keypad Panic Keys
This option allows the two-button panic key operation selected at a keypad to send 
the Panic, Emergency, or Fire message to the central station receiver. Select YES to 
enable the two-button panic operation. To disable the two-button panic operation, 
select NO. Default is YES.
28.17 
Occupied Premises
Select YES to allow the panel to automatically disarm the interior area(s) when 
arming all areas and a perimeter zone is not tripped during the exit delay.
This False Alarm Reduction feature keeps a user from arming the entire system 
when they do not exit and remain in the premises. Select NO to not automatically 
disarm interior area(s). Default is NO.
28.18 
Use False Alarm Question
Select YES to display IS THIS A FALSE ALARM?  NO YES at the keypad in place of 
CANCEL  VERIFY when a burglar alarm occurs. Select NO to display CANCEL VERIFY 
for burglar alarms. This operates for ALL/PERIM and HOME/SLEEP/AWAY arming 
systems. Default is YES.
28.19 
Weather Zip Code
This option allows local U.S.A. weather updates to display in the Status List on the 
keypad. Enter the zip code of the user at this option. When no number is entered 
weather conditions are not displayed. Default is 
-.
Bell Options
29.1 
Bell Options
This section allows you to program the panel bell output functions. If using the 
Model 1135 or 1135DB Wireless Siren, the Trip with Panel Bell option should be 
selected in the Output Information programming for the siren.
29.2 
Bell Cutoff Time
Enter the maximum time from 1 to 15 minutes that a wireless output remains on. If 
the output is manually silenced or the system is disarmed, the cutoff time is reset. 
Default is 5.
29.3 
Automatic Bell Test
When YES is selected, the 1135/1135DB wireless siren is turned on for two seconds 
when all areas in the system are armed. The Bell Test only occurs when the areas 
are armed from a keypad. Arming performed from an Arming zone or remotely 
from Remote Link™ does not activate the Bell Test.
Closing Wait operation
When Bell Test is set to YES, the closing wait function also operates. Closing Wait 
provides a delay time before a monitored system arms until the panel receives an 
acknowledgment of the closing report from the central station receiver. During the 
delay, the keypad displays ONE MOMENT .  .  . Once the closing is acknowledged, 
the keypad buzzes for one second and then displays the ALL SYSTEM ON message. If 
communication fails, the message LOCAL ALARM ONLY appears.
29.4 
Bell Output
Enter the output number (51-54, 61-64) for an 1116 or 1117 wireless output  
when needed to follow the on and off condition of the bell action. Enter 0  
(zero) to disable.
Note: When BELL ACTION below is set to T for Temporal Code 3, this Bell Output 
action will be Pulse for wireless outputs 51-54 and 61-64.
29.5 
Bell Action
This defines the type of Bell Action from zone alarms that will occur. Trouble 
conditions do not activate Bell Action. There are seven zone types you can  
program individually for Bell Output. To provide a steady Bell Output, enter S.  
For a pulsed output, enter P. For a Temporal Code 3 output, enter T and for no  
bell action, enter N.
29.5.1 Fire
Defines Bell Action for Fire Type Zones. The default is set at T.
29.5.2 Burglary
Defines Bell Action for Burglary Type Zones. The default is set at S.
KPD PANCS NO YES
 
OCCUPIED PREMISE
  
NO   YES
 
USE FALSE ALARM
QUESTION? NO YES  
 
ENTER WEATHER  
ZIP CODE:  -
BELL OPTIONS
BELL OPTIONS
BELL CUTOFF:
5
BELL TEST  NO YES
BELL OUTPUT:
0
BELL ACTION . . .
FIRE    TYPE:
T
BURGLARY TYPE:
S