Pressure Systems, Inc.                                                                                        Model 9116 User’s Manual 
 
 
 
Page 62 
 
www.PressureSystems.com 
The optional ipaddr parameter is normally unspecified, causing it to default to use  
the IP address of the current TCP/IP connection.  That way the host need not  
have to be aware of its own IP address.  This parameter is provided in case a 
special host has multiple network interfaces and wants to use more than one.   
When used, ipaddr requires four dotted numeric fields (d.d.d.d). Each d is a 1-3  
digit decimal number in the range 0-255.  The ipaddr = 255.255.255.255 is best  
avoided, unless the UDP datagrams of streams are to be broadcast to all  
network nodes. 
 
 
Example: 
● 
 
Configure all streams to be delivered via UDP/IP protocol.  Host expects the UDP  
 
 
datagrams to arrive via port 7500.  The IP Address of the current TCP/IP  
 
 
connection is also used to send each UDP datagram. 
 
“c 06 0 1 7500” 
 
  Read 
response: 
 
 
 “A” 
 
● 
 
Configure all streams to be delivered via the default TCP/IP protocol.  
 
“c 06 0 0” 
 
  Read 
response: 
 
 
 
“A”