Atmel SAM4S-XPLD Atmel ATSAM4S-XPLD ATSAM4S-XPLD Hoja De Datos

Los códigos de productos
ATSAM4S-XPLD
Descargar
Página de 1125
 863
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
Figure 38-7. Complementary Output Waveforms
38.6.2.5 Output Override
The two complementary outputs DTOHx and DTOLx of the dead-time generator can be forced to a value defined by the
software.
Figure 38-8. Override Output Selection
The fields OSHx and OSLx in the 
 (PWM_OS) allow the outputs of the dead-time
generator DTOHx and DTOLx to be overridden by the value defined in the fields OOVHx and OOVLx in the
 (PWM_OOV).
The set registers 
and PWM_OSSUPD) enable the override of the outputs of a channel regardless of other channels. In the same way, the
clear registers 
 (PWM_OSC
and PWM_OSCUPD) disable the override of the outputs of a channel regardless of other channels.
By using buffer registers PWM_OSSUPD and PWM_OSCUPD, the output selection of PWM outputs is done
synchronously to the channel counter, at the beginning of the next PWM period.
DTHx
DTLx
output waveform OCx
CPOLx = 0
output waveform DTOHx
DTHIx = 0
output waveform DTOLx
DTLIx = 0
output waveform DTOHx
DTHIx = 1
output waveform DTOLx
DTLIx = 1
DTHx
DTLx
output waveform OCx
CPOLx = 1
output waveform DTOHx
DTHIx = 0
output waveform DTOLx
DTLIx = 0
output waveform DTOHx
DTHIx = 1
output waveform DTOLx
DTLIx = 1
DTOHx
OOVHx
OOOHx
OSHx
0
1
DTOLx
OOVLx
OOOLx
OSLx
0
1