Metrologic Instruments MS1690 Focus Manuel D’Utilisation

Page de 56
 
 
7
I
NSTALLING
 
THE 
S
CANNER TO THE 
H
OST 
S
YSTEM
 
 
RS232 
 
1.  Turn off the host device.  
 
2.  Plug the male 10-pin RJ45 end of 
the PowerLink cable into the 10-pin 
socket on the scanner.  There will be 
an audible click when the connector 
lock engages. 
 
3.  Connect the 9-pin D-type connector 
of the communication cable to the 
proper COM port of the host device. 
 
4.  Plug the power supply into the power 
jack on the PowerLink cable.  
 
Check the AC input 
requirements of the power 
supply to verify the voltage 
matches the AC outlet. 
The outlet must be located 
near the equipment and be 
easily accessible. 
 
5.  Connect AC power to the transformer. 
 
6.  The scanner will start to initialize.  All LEDs (yellow, white, and blue) will light 
for approximately two seconds then start to alternately flash.  When the 
scanner has finished initializing the LEDs will stop flashing and the unit will 
beep three times indicating that the scanner is ready for use. 
 
7.  Turn on the host device. 
 
Plugging the scanner into a port on the host system does not guarantee 
that scanned information will be communicated properly to the host 
system.  The scanner is shipped from the factory configured with default 
settings.  Please refer to the MetroSelect Single-Line Configuration 
Guide (
MLPN 
00-02544) or MetroSet2’s help files for instructions on 
changing the scanner’s configuration.  In addition, please check that the 
scanner and host system are using the same communication protocol.  
 
See power source caution statement located on page 6 of this manual. 
 