NSTALLING THE 
S
CANNER TO THE 
H
OST 
S
YSTEM
 
 
Stand Alone Keyboard 
 
1.  Turn off the host device.  
 
2.  Plug the male 10-pin RJ45 end of 
the PowerLink cable into the 10-pin 
socket on the scanner.  There will be 
an audible click when the connector 
lock engages. 
 
3.  Plug the other end of the 
communication cable into the host’s 
keyboard port. 
 
4.  Plug the external power supply into 
the power jack on the PowerLink 
cable.  
 
Check the AC input 
requirements of the power 
supply to verify the voltage 
matches the AC outlet.  The 
outlet must be located near 
the equipment and be easily 
accessible. 
 
5.  Connect AC power to the transformer.  
 
6.  The scanner will start to initialize.  All LEDs (yellow, white, and blue) will light 
for approximately two seconds then start to alternately flash.  When the 
scanner has finished initializing the LEDs will stop flashing and the unit will 
beep three times indicating that the scanner is ready for use. 
 
7.  Turn on the host device. 
 
Plugging the scanner into a port on the host device does not guarantee 
that scanned information will be communicated properly to the host 
device.  The scanner is shipped from the factory configured with default 
settings.  Please refer to the MetroSelect Single-Line Configuration 
Guide (
MLPN 
00-02544) or MetroSet2’s help files for instructions on 
changing the scanner’s configuration.  In addition, please check that the 
scanner and host system are using the same communication protocol.   
 
See power source caution statement located on page 6 of this manual. 
 
Figure 8.