Manuel D’UtilisationTable des matières1.0 Introduction7Figure 1 Typical installation of OpenComms NIC card71.1 OpenComms Compatibility8Table 1 OpenComms availability9Table 2 Specifications102.0 Installation112.1 Retrofit Kit112.2 Self-Contained Unit11Figure 2 Connections112.3 User Connections for OpenComms NIC122.3.1 Network Port122.3.2 BMS Port122.3.3 Configuration Port / Service Terminal12Accessing the Configuration Port13Figure 3 Null modem cable diagram13Figure 4 NIC main menu in HyperTerminal143.0 System Configuration153.1 DIP Switch Settings153.2 Service Terminal15Table 3 Service terminal navigation16System Information Menu17Network Settings Menu17BOOTP and DHCP Mode17SNMP Communications Menu17Web Server18Telnet18Change User Name / Password18Firmware Updates Menu18Factory Settings Menu18Auxiliary Communications194.0 Operation204.1 SNMP204.2 Liebert Global Products MIB204.3 RFC 1628 UPS MIB214.3.1 SNMP Traps214.4 MIB234.5 HTTP234.6 Modbus RTU234.7 System Reset234.8 Diagnostics24Figure 5 LED locations245.0 Modbus Communications and Connectivity255.1 Implementation Basics255.1.1 Constraints255.2 Transmission Format255.3 Physical Connection26Figure 6 Typical maximum installation26Figure 7 Exceeding maximum specifications275.4 Modbus Slave Functions275.4.1 Data Type275.4.2 Function Code Support285.4.3 Read/Write Holding Registers (0x03, 0x06, 0x10)285.4.4 Read Input Registers (0x04)285.4.5 Read, Set Coil Status (0x01, 0x05, 0x0F)285.4.6 Read Input Status (0x02)295.4.7 Error Handling29Table 4 Exception response29Modbus Packet Formats295.5 RTU Framing Examples305.5.1 Read Registers (Function Code 0x03 & 0x04)305.5.2 Write single holding register (Function Code 0x06)306.0 NIC Setup and Testing316.1 Jumper Placement31Figure 8 Jumper positions316.2 Testing the Network326.3 Service Terminal Troubleshooting326.4 SNMP Troubleshooting326.5 Web Troubleshooting336.6 Modbus Troubleshooting337.0 Firmware Updates347.1 Establishing Communication-Necessary Components347.2 Establishing Communication-Service Terminal Settings357.3 Firmware Update Procedure368.0 External Enclosures398.1 Power Connection39Figure 9 NIC-ENCL1 internal view398.2 Communication Connection399.0 Retrofit Installation409.1 Environmental Installation409.1.1 Deluxe System/340Figure 10 Deluxe System 3 NIC installation40Figure 11 Deluxe System 3 chilled water control cavity41Figure 12 ICS control cavity41Figure 13 Challenger installation location429.2 System Wiring (SM, AM, AG Microprocessors)439.3 Power Connection (SM, AM, AG Microprocessors)439.3.1 Power Connection (Level 0 and Level 10 Microprocessors)439.3.2 Communication Connection (SM, AM, AG Microprocessor)449.3.3 Communication Connection (Level 0 and Level 10 Microprocessors)449.4 Himod (LNA)44Figure 14 Himod NIC installation location449.4.1 System Wiring (Himod)459.4.2 Power Connection (Himod)459.4.3 Communication Connection (HiMod)459.5 Mini-Mate2459.6 Emerson Network Power (CEMS100 / LECS15)469.7 UPS Installation469.8 Npower469.8.1 Power Connection for NPower469.8.2 Communication Connection for NPower46Figure 15 NPower UPS NIC installation479.9 7200 UPS48Figure 16 7200 UPS NIC installation499.10 HiPulse UPS50Figure 17 HiPulse installation519.11 Static Switch252Figure 18 STS2 typical NIC location52Figure 19 STS2 NIC installation, 800-1000A units52Figure 20 STS2 NIC installation, 100 - 600A units539.12 STS539.13 PDU and DataWave with PMP & EPMP53Taille: 2,2 MoPages: 56Language: EnglishOuvrir le manuel