Plot
Read the plot
In general, the registration between colors should not show abrupt changes. A smooth variation along the 
scan axis is due to Media Expansion.
Abrupt changes signal serious problems with the scan axis encoder strip.
In the cyan band, the encoder strip causes‚ glitches‚ about 3 mm apart that correspond to the 
printhead arrays.
In the yellow and magenta band, the abrupt glitch measures 135 mm apart.
Generally, you should always find both of these glitches if there is a problem.
NOTE:
If you recognize both of these patterns in the same plot, even slightly, replace the 
encoder strip. There is absolutely no image quality tolerance for this problem  page 631.
135 mm
3 mm