Installation Notes
Near Metal - The typical read distance specification (9.5 inches) refers to operation without metal in the vicinity
of the Reader. Use the metal compensation Jumper, P1, if mounting within 2” of a metal surface.
Place the jumper on P1 between pins 1 and 2 when mounting to a metallic surface or to a junction box with a
metal cover plate.  Otherwise, the jumper should be between pins 2 and 3, the default position (see figure 1).
The ProxPro Plus generates a magnetic field on both sides of the reader.  Any metal  that conducts electricity,
especially metal that contains iron, steel or copper, will interfere with the field and reduce the effective read
range (this will happen even if the metal is behind the Reader).
For optimum performance, the Reader should be mounted at least 4 inches away from any metallic surface
7”x7" or larger. Incidental metal such as aluminum and steel studs and conduit can be compensated. Avoid
installing conduit and other metal hardware within 1 inch of the back of the Reader.
Power Supply - The ProxPro Plus Reader  can  be operated over the full range of 10-28.5VDC, 150mA. The
Read distance will be slightly higher on 24VDC when compared to 12VDC.  A linear supply is recommended.
Noise from devices such as switching power supplies, computer monitors and arc welders can reduce the read
range or make the unit inoperable.  Keep these devices at least 10 ft away from the Reader.
Testing - After wiring the Reader and power supply, the Reader is ready to be tested.  Power up the Reader
and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one long delay. This
indicates that the micro-controller unit is working properly.  Present an ID card to the Reader and the LED
should momentarily turn green and the Beeper will sound, indicating a read of the card.  If the Reader
LED/Beeper is controlled by the Host refer to the Host description of the LED operation.
Tamper Switch - Connect the tamper switch to the Host, if available on the Host. When the cover is removed,
the tamper switch is released. The switch contacts available on pins 10 and 11 are either normally open or
normally closed dependent upon the position of the jumper on P3. Install the jumper to connect pins 1 and 2 if
you need the normally open contact. Select the 2-3 position if you need the normally closed contacts. The
normally open and normally closed refer to the condition of the switch when the case is open. The contacts are
rated for 50 mA at 28.5 VDC.
Cable Notes
1.
When using 5 conductor cable, the power supply and Host must have a common ground (voltage
reference).
2.
6 conductor cable is required when using the "Hold" function  (Alpha 1296 C or equivalent).
3.
7 conductor cable is required when the "Hold" function is used, and the power supply and Host "ground" are
separate (Alpha 1297 C or equivalent).
4.
The Wiegand interface cable should be restricted to a length 500 feet. The inner diameter of the cable
grommet will accommodate a cable with an outer diameter of .300 inches (maximum).
5.
The Cable shield should be connected to the Return Ground on Reader TB1- 5, and left floating at the
panel or power supply end of the cable. This configuration is the best for shielding the reader cable from
external interference and reducing the likelihood of the Reader causing interference.