HID Global Corporation 535Y Manuale Utente

Pagina di 11
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (714) 598-1600  (800) 237-7769  FAX (714) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPro Plus Wiegand Reader Installation Manual 6030-900 REV G              5 of 10
Installation Procedure
Cable Installation
Preparation - Determine the desired mounting location for the reader. The reader can be mounted directly to a
glass panel using tape (Glass Mount),  to the mullion of a glass panel using a side mount bracket (Side Mount),
or to an electrical gang box (Wall Mount).
Install Cable - Route the interface cable from the mounting location to the power supply and/or the Host. Refer
to “Cable Notes” to determine the best cable to use.
Cable Preparation - Prepare the cable by cutting the cable jacket back 2 inches and strip the wires 1/4 inch.
Tinning the wires is not required.
Cable Connections - Disassemble the reader by removing the 4 #8 screws from the back.  For the side mount
reader feed the cable through the mounting bracket and the ¼” diameter grommet, this should be a tight fit.
For the rear mount reader feed the cable through the strain relief connector and tighten down. Connect the
wires to the terminal strip with the minimum length necessary; do not leave extra loops of wire inside the
Reader housing. Connect the Reader to the Host according to the terminal description of TB1 below.  The
descriptions are also labeled on the PCB guard in the reader. Connect the drain line of the shield to terminal 5
(Return). If the drain line is bare, cover it with heat shrink or tape to avoid short circuits to the other wires. The
host end of the drain line should be left open.
1
2
3
4
5
6
7
8
9
10
11
+DC
Ground
Data0
Data1
Return
(Shield)
Green
LED
Red
LED
Beeper
Hold
Tamper
Common
Tamper
Select
Red
Black
Green
White
Drain
Orange
Brown
Yellow
Blue
---
---
 
 FIGURE 1
 Cable Terminal Connections
1
8
S W 1
1
P 2
+D C
BEEPER
G R N  LED
RED  LED
D A TA  1
G R O U N D
RETUR N
D A TA  0
3
P 1
1
TA M PER  SEL
TA M PER  C O M M
P 3
H O LD
3
1
1 /4 " C A B LE
G R O M M ET
SID E EX IT
REA R  EX IT
STR A IN  RELIEF
C O N N EC TO R
1
1 2
TB 1