4.12  DS1A - RESET: 
4.12.1.  Indicates that the unit is in standby. 
4.13  DS1B - CYC END: 
 
4.13.1.  Flashing (with pulsating beeper) cycle end. Indicates that the unit has completed 
its cycle. 
4.14  DS2A - DUAL: 
4.14.1.  Indicates that the DUAL rate mode (MAIN and TOPPING) is selected. 
4.15  DS2B - MAIN:   
 
 
4.15.1.  Indicates that the unit is in MAIN charge. 
4.16  DS3A - SINGLE:  
 
4.16.1.  Indicates that the SINGLE rate mode (Topping) is selected. 
4.17  DS3B - TOP: 
 
 
 
4.17.1.  Indicates that the unit is in TOPPING charge. 
4.18  DS4A - AUTO:   
 
 
4.18.1.  Indicates that the AUTO (analysis) mode is selected. 
4.19  DS4B - DISCH:   
 
4.19.1.  Indicates that the unit is in AUTO discharge. 
4.20  DS5A - FULL: 
 
 
 
4.20.1.  Indicates that the FULL (deep cycle) mode is selected. 
4.21  DS5B - DISCH:   
 
4.21.1.  Indicates that the unit is in FULL discharge. 
4.22  DS6A - CAP FAIL: 
 
4.22.1.  Indicates that the battery has failed to meet capacity. 
4.23  DS6B - OPEN LIM: 
 
4.23.1.  Indicates that either the charge or discharge limiters are open. 
4.24  DS7A - OVR TEMP: 
 
Indicates Overtemp fault. 
4.24.1.  Continuous (no beeper): Indicates that the TEMP-PLATE is not connected (or 
open). 
4.24.2.  Flashing: Indicates battery temperature in excess of 45
o