Using Intelligent Input Terminals
Oper
ations
a
nd Moni
tor
ing
4–26
Analog Input 
Current/Voltage 
Select
The [AT] terminal operates in conjunction with parameter setting A005 to determine the analog 
input terminals that are enabled for current or voltage input. Setting A006 determines whether 
the signal will be bipolar, allowing for a reverse direction range. Note that current input signal 
cannot be bipolar and cannot reverse direction (must use [FW] and [RV] command with current 
input operation). The following table shows the basic operation of the [AT] intelligent input. 
Please refer to 
 for more information on bipolar input 
configuration, and the operating characteristics of analog inputs.
Opt.
Code
Symbol
Function Name
Input 
State
Description
16
AT
Analog Input 
Voltage/current 
Select
ON
• With A005 = 00, [AT] will enable 
terminals [OI]–[L] for current input,
4 to 20mA
• With A005=01, [AT] will enable termi-
nals [O2]–[L] for voltage input
OFF
Terminals [O]–[L] are enabled for voltage 
input (A005 may be equal to 00 or 01) in 
this case
Valid for 
inputs:
C001, C002, C003, C004, 
C005, C006, C007, C008
Required 
settings:
A001 = 01
A005 = 00 / 01
A006 = 00 / 01 / 02
Notes: 
• 
Be sure to set the frequency source setting 
A001=01 to select the analog input terminals.
5
3
1
7
6
4
2
8
FW
TH
PLC
CM1
P24
CM1
See I/O specs on page 
Example: (Default input configuration 
shown—see page 
. Jumper position 
shown is for –xFU/-xFR models; for –xFE 
models, see page 
.)
AT