Installation Instructions
14
B. 
OUTSIDE TOP EXHAUST 
(Vertical Duct)
B1.
ATTACH THE MOUNTING PLATE 
TO THE WALL
Attach the plate to the wall using toggle bolts. At least 
one wood screw must be used to attach
the plate to a wall stud.
1.
Remove the toggle wings from the bolts.
2.
Insert the bolts into the mounting plate through the 
holes designated to go into drywall and reattach 
the toggle wings to ¾" onto each bolt.
To use toggle bolts:
3.
Place the mounting plate against the wall and 
insert the toggle wings into the holes in the wall to 
mount the plate.
NOTE: Before tightening toggle bolts and wood 
screw, make sure to coincide bottom line of the 
Mounting plate with Horizontal line of “Rear wall 
Template” and then the Mounting plate is properly 
centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers 
between the back of the mounting plate and the wall.
4.
Tighten all bolts. Pull the plate away from the wall 
to help tighten the bolts.
INSTALLATION OVERVIEW
B1. Attach Mounting Plate to Wall
B2. Prepare Top Cabinet
B3. Adjust Blower
B4. Check Damper Operation
B5. Mount Microwave Oven
B6. Adjust Exhaust Adaptor
B7. Connect Ductwork
Mounting 
Plate
Wall
Toggle Wings
Toggle 
Bolt
Spacing for Toggles More 
Than Wall Thickness
Bolt End