Puls ML60.241 Power Supply Guia De Especificação

Página de 22
 
 
ML60.241
 
 
MiniLine 
 
24V,
 
2.5A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
14.  E
NVIRONMENT
 
 
Operational temperature 
*)
 
-10°C to +70°C (-32°F to 158°F) 
reduce output power according Fig. 14-1
Storage temperature 
-40°C to +85°C  (-40°F to 185°F) 
for storage and transportation 
Output de-rating 
1.5W/°C 
60-70°C   (140°F to 158°F) 
Humidity 
**)
 
5 to 95% r.H. 
IEC 60068-2-30 
Vibration sinusoidal 
2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 
2 hours / axis 
IEC 60068-2-6 
Shock 
15g 6ms, 10g 11ms 
3 bumps / direction, 18 bumps in total 
IEC 60068-2-27 
Altitude 
0 to 2000m  (0 to 6 560ft) 
without any restrictions 
 
2000 to 6000m  (6 560 to 20 000ft) 
reduce output power or ambient temperature  
see Fig. 14-2 
IEC 62103, EN 50178, overvoltage category II 
Altitude de-rating 
4W/1000m or 5°C/1000m 
> 2000m (6500ft), see Fig. 14-2
Over-voltage category 
III 
IEC 62103, EN 50178, altitudes up to 2000m  
 
II 
altitudes from 2000m to 6000m 
Degree of pollution 
IEC 62103, EN 50178, not conductive 
*)   Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit. 
**)   Do not energize while condensation is present 
 
 
Fig. 14-1   Output power vs. ambient temp. 
 
Fig. 14-2   Output power vs. altitude 
 
0
-10
0
40
70°C
10
20
30
40
50
60W
60
Ambient Temperature
20
Allowable
Output Power
 
0
0
2000
4000
6000m
10
20
30
40
50
60W
Altitude
A... Tamb < 60°C
B... Tamb < 50°C
C... Tamb < 40°C
A
B
C
Allowable
Output Power
 
 
 
15.  P
ROTECTION 
F
EATURES
 
 
Output protection 
Electronically protected against overload, no-load and short-circuits 
*)
 
Output over-voltage protection typ. 
31Vdc 
max. 32.5Vdc 
In case of an internal power supply fault, a redundant 
circuit limits the maximum output voltage. In such a 
case, the output shuts down and stays down until the 
input voltage is turned off and on again. 
Output over-current protection electronically 
limited 
 
Degree of protection 
IP 20 
EN/IEC 60529 
Penetration protection 
> 2.5mm in diameter 
e.g. screws, small parts 
Over-temperature protection 
not included 
 
Input transient protection 
MOV 
Metal Oxide Varistor 
Internal input fuse 
T3.15A H.B.C. 
not user replaceable 
*)   In case of a protection event, audible noise may occur. 
Sep. 2010 / Rev. 1.0  DS-ML60.241-EN 
All parameters are specified at 24V, 2.5A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
12/22