Puls ML15.121 Power Supply Guia De Especificação

Página de 23
 
 
ML15.121
 
 
MiniLine-2 
 
12V,
 
1.3A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
14.  E
NVIRONMENT
 
 
Operational temperature 
*)
 
-10°C to +70°C (14°F to 158°F) 
Reduce output power according Fig. 14-1
 
Storage temperature 
-40 to +85°C  (-40°F to 185°F) 
For storage and transportation 
Output de-rating 
0.4W/°C 
60-70°C   (140°F to 158°F) 
Humidity 
**)
 
5 to 95% r.H. 
IEC 60068-2-30 
Vibration sinusoidal 
2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 
2 hours / axis 
IEC 60068-2-6 
Shock 
30g 6ms, 20g 11ms 
3 bumps / direction, 18 bumps in total 
IEC 60068-2-27 
Altitude 
0 to 6000m  (0 to 20 000ft) 
Reduce output power or ambient temperature 
above 2000m sea level. 
Altitude de-rating 
1W/1000m or 5°C/1000m 
above 2000m (6500ft), see Fig. 14-2
Over-voltage category 
III 
IEC 62103, EN 50178, altitudes up to 2000m  
 
II 
Altitudes from 2000m to 6000m 
Degree of pollution 
IEC 62103, EN 50178, not conductive 
LABS compatibility 
The unit does not release any silicone or other LABS-critical substances and is suitable for 
use in paint shops. 
*)   Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit. 
**)   Do not energize while condensation is present 
 
 
Fig. 14-1   Output power vs. ambient temp. 
 
Fig. 14-2   Output power vs. altitude 
 
0
-10
0
20
40
70°C
2.5
5.0
7.5
10.0
12.5
15W
60
Ambient Temperature
Allowable
Output Power
 
0
0
2000
4000
6000m
2.5
5.0
7.5
10.0
12.5
15W
Altitude
A... Tamb < 60°C
B... Tamb < 50°C
C... Tamb < 40°C
A
B
C
Allowable
Output Power
 
 
Mar. 2013 / Rev. 2.1  DS-ML15.121-EN 
All parameters are specified at 12V, 1.3A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
12/23