The Programmer System can be used to: 
  Interrogate, adjust, and monitor the therapies being delivered by the IPG 
  Monitor IPG status information such as battery voltage and end of service indicators 
Navigating 
Use the pointing device to navigate the Programmer Software.  In this section, the word “click” indicates 
depressing the left pointing device button to perform the required action. 
User Login 
After powering up the programmer you will be requested to login.  Click the CVRx User and enter the 
password. 
Starting the Application 
Double-click the “CVRx” icon labeled “CVRx Launcher” to start the software application. 
NOTE: When the software is started, it automatically looks for the Programmer Interface. If the 
software cannot find the Programmer Interface, a warning message will be displayed.  Plug the 
Programmer Interface into the computer USB port before continuing. 
Connection Dialog 
When the Connection Dialog window appears, verify that the system  time,  date, and time zone  on the 
programmer is correct.  If not, click the “Set…” button to correct the time. 
The Discovery status should indicate  “In progress…”  While Discovery is in progress,  all  Neo  and Neo 
Legacy IPG devices within telemetry range will be displayed in the list of IPGs discovered. 
In order to establish communication, first select  the  device by clicking on the row containing  the  desired 
patient identification and serial number information.  This will highlight the row.  Ensure that the patient 
identification  and  serial number of the selected IPG matches that of the device implanted in the patient 
being treated.  If an incorrect device is selected, a telemetry link will be established with an IPG that is not 
the one implanted in the patient being treated. 
Note: If the desired IPG does not appear on the list, move the Programmer Interface  closer to the patient 
until the device appears. 
After the proper IPG is selected, click on the Connect button to start communication.  The application will 
then display the Main Screen. 
The IPG is automatically interrogated by the Software Application so that the current device settings are 
always available. 
If an IPG error is encountered, a device error status will be displayed. 
An automated adjustment of the IPG day clock takes place at the beginning of a session. The software sets 
the time of day clock/calendar of the IPG equal to the computer time of day clock/calendar.