Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
10 VAC, 15 or 0 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUNSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Disconnect power.
Remove terminal box cover.
Remove the knockout in the terminal box and install a UL 
listed or CSA approved ½” strain relief.
Run home power supply wiring through ½” strain relief 
 
into terminal box. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Use UL listed wire connectors and connect white wires 
(B) together.
Use UL listed wire connectors and connect black wires 
(C) together. 
1.
2.
3.
4.
5.
6.
Electrical Shock Hazard 
Electrically ground blower. 
Connect ground wire to green and yellow ground wire 
in terminal box. 
Failure to do so can result in death or electrical shock. 
Connect green (or bare) ground wire from home power 
supply to the 2 yellow-green ground wires (D) in terminal 
box using UL listed wire connectors.
Tighten strain relief screw.
Install terminal box cover.
Reconnect power. 
 
Mounting the duct cover
Position the duct cover over the mounted hood.
Slide the bottom of the duct into the glass area.
Position the top of the duct over the duct mounting 
 
bracket. If a telescopic duct cover is used, grab the 
 
upper part of the telescopic duct cover, pull it and place it 
 
in the duct cover mounting bracket.
Secure the top of the duct with 2 assembly screws  
 
provided.
7.
8.
9.
10.
A
B
C
D
E
A. UL listed wire connectors
B.White wires
C. Black wires
D. Green (or bare) wire connected to
yellow-green wires
E. Home power supply