Elica EVL43XS1 安装指导

下载
页码 40
10
Control and features
This hood is equipped with an electronic motor and lamp
control. The control is able to set 3 different fan speeds,
turn ON/OFF light and has a timer function. In the following
drawing are described the main key functions. 
 
Control panel description 
 
 
 
 
 
 
1. Timer Key
The default timer setting is 10 minutes, and it can be 
 
adjusted between 20 minutes and 1 minute.
After pressing the timer key, the control enters to a timer 
 
setup mode, and user can adjust the timer countdown 
time with the “-” and “+” keys within 5 seconds. The timer 
 
can be initiated immediately pressing the timer key, after 
 
setting the timer duration or pressing the timer key twice 
(default 10 minutes setting).
If not action occurs within 5 seconds the countdown will start.
During the timer setup the “-” and “+” keys are dedicated 
 
to the timer and no motor action will occur.
Once initiated the timer, it can be cancelled by pressing 
 
the timer key again. 
. Light Key
Press lamp key to turn ON the light (Lamp state  
previously OFF).
Press lamp key to turn OFF the light (Lamp state  
previously ON). 
3. Display
Shows the hood settings. 
4. “-” Key. Speed Decrease / OFF
This key is used to decrease the fan speed, or turn OFF the fan.
The fan will turn OFF if the “-” key is pressed and the 
hood was in the first speed.
If the fan is at second speed and the “-” key is pressed, 
the fan will be set to first speed.
If the fan is at third speed and the “-” key is pressed, the 
 
fan will be set to second speed.
If the fan is OFF and the “-” key is pressed, the control 
 
backlight will light up.
 
5. “+” Key. Speed Increase / ON
This key is used to increase the fan speed, or turn ON the fan.
The fan will turn ON if the “+” key is pressed and the  
hood was OFF.
If the fan is at first speed and the “+” key is pressed,  
 
the fan will be set to second speed.
If the fan is at second speed and the “+” key is pressed,
 
the fan will be set to third speed.
If the fan is at third speed and the “+” key is pressed,  
 
a beep will sound.
 
Special functions
 
Clock programming
The clock can be reprogrammed at any time except  
 
during an active timed function.
The clock can be displayed in a twelve hour format and 
 
valid clock times are from 1:00 to 12:59.
The clock can be reprogrammed pressing the “Timer” 
Description of the hood & 
Controls 
 
 
 
 
 
 
 
 
 
 
Control panel
Cover Lamp
Grease filter release Handle
Grease filter
Duct cover
Duct cover grid
1.
2.
3.
4.
5.
6.
1 2 3