Communication Manager Maintenance-Object Repair Procedures
1134 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
EMG-XFER (Emergency Transfer)
S8700 | 8710
 / 
S8500
S8700 | 8710
 / 
S8500
Emergency Transfer (SCC Cabinets)
The system provides the ability to cut designated analog phones through to CO trunks if the 
switch cannot provide even minimal phone service. This ability is known as Emergency 
Transfer. The EMG-XFER MO tracks the control of Emergency Transfer. There is one 
EMG-XFER MO for the port network. Emergency Transfer can be controlled by the system or 
can be manually controlled via the Emergency Transfer switch located on the Maintenance 
(TN775) circuit pack. A manual ON position (up) generates a Major alarm. A manual OFF 
position (down) generates a Warning alarm. Unless a technician is currently working on the 
system, the switch should be left in the auto position.
Error Log Entries and Test to Clear Values
MO Name in 
Alarm Log
Alarm 
Level
Initial SAT Command to Run
1
1. UU is the universal cabinet number listed in the PORT field of the Alarm or Error Log.
Full Name of MO
EMG-XFER
MAJ
test environment UU
Emergency Transfer
EMG-XFER
WRN
test environment UU
Emergency Transfer
Table 386: Emergency Transfer Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
0
Any
Any
Any
test environment sh r 
1
0
Emergency Transfer Query 
(#124) 
MAJ
ON
test environment r 3
257 (
0
Emergency Transfer Query 
(#124)
WRN
ON
test environment r 3