Modem Pool Conference Test (#97)
This test is destructive.
The Modem Pool Conference test checks most of the switching and gain control functions 
provided by the NPE circuit in the analog section of the conversion resource. This test 
conferences a 1004-Hz tone through the NPE, looping it back so that it can be verified with a 
Tone Detector circuit
Table 623: Test #97 Modem Pool Conference Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
System resources required for this test are not available.
1000
ABRT
System resources required to run this test are not available. The port 
may be in use on a valid call. 
1. Determine whether the port is available for testing.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out-of-service 
due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present, or some 
Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 
times.
1004
ABRT
The port has been seized by a user for a valid call. Determine whether 
the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABRT
The test did not run due to a previously existing error on the specific port 
or because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the 
circuit pack, and attempt to diagnose previously existing errors.