Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
704 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Layer 1 Transmission Error Counter Test (#624)
This test reads and clears the BRI port’s Layer 1 Transmission error counter maintained on the 
BRI-LINE circuit pack.  This counter is incremented by the circuit pack when it detects a Layer 1 
transmission problem.  The test passes if the value of the counter is 0 (that is, the error is 
cleared).  If the counter is not zero, the test fails, and the value of the counter is displayed in the 
Error Code field.
This error is most likely due to a problem with the wiring or the endpoint or adjunct (verify that 
the wiring meets the configuration rules defined in DEFINITY® Communications System 
Generic 1 and Generic 3i Wiring, 555-204-111
.  It do
es not indicate a problem with the 
ISDN-BRI circuit pack.  This test is useful for verifying the repair of the problem.
2012
ABRT
Internal system error.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1
FAIL
The BRI-LINE circuit pack reports that it has detected an overcurrent 
condition and has turned off the EPF.
1. As necessary, check and repair the wiring between the circuit pack and 
the endpoint or adjunct.  Check the endpoints and replace one or both 
sets if the sets are drawing too much current.  Execute test port 
location
 and review the results of the EPF Inquiry test to verify the 
repair.  If this test is still failing, proceed to step 2.
2. Execute test port location, and review the results of the Level 1 
Status Inquiry test.  If this test is also failing, then follow the repair 
procedure for the Level 1 Status Inquiry test.  Otherwise, escalate this 
problem to the next tier.
PASS
The Electronic Power Feed Inquiry test reports that the EPF is on.
Table 236: Test #622 Electronic Power Feed Inquiry  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2