CO-TRK (Analog CO Trunk)
Issue 1 June 2005
843
 
Note:
Note:
A Demand Diagnostic test (#3) will always return a PASS indication for CO-TRK/
CO-BD [TN747B] version 8 or greater.  However, any errors produced as a result 
of this test will be logged and produce no alarms.
If errors logged by Test #3 are the only complaints against this trunk, then the 
system technician should check if MFT/Range Extenders are being used.  If 
extenders are present, then there is a good chance that there is excessive loop 
current, which will cause Test #3 to log errors.
However, all else being normal, these errors should not affect the customer.
Note:
Note:
The ATMS tests are not part of either test sequence.  They are run either on 
demand with test analog-testcall or by the ATMS schedule.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
Audit Update test (#36)
X
X
ND
Transmission test - ATMS (#844-848) 
S8300
 / 
G700
 aborts with Error Code 1412
ND
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
 2 of 2
Table 288: Test #0 Dial Tone Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.