Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
912 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
61446
FAIL
Battery feed test failed. A loop current fault was detected. This is most 
probably an incoming CO-line problem. This failure code is only reported 
by the TN2139 Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none is detected refer 
the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the DID port. 
Replace the circuit pack.
61456
FAIL
Battery feed test failed. An on-board problem was detected. This port is 
out-of-service.
1. Replace the circuit pack or media module.
61472
FAIL
Battery feed test failed. A problem with the incoming CO-line was 
detected.
1. Check the incoming CO-line for proper operation. If warranted, refer 
the problem to the CO.
2. If the CO-line is not at fault, the failure must be on the DID port. 
Replace the circuit pack or media module.
PASS
Current flow was detected for this port.
1. User-reported troubles on this port should be investigated using other 
port tests and by examining connections.
2. Refer problem to the CO.
Table 310: Test #35 Port Diagnostic Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3