82 • Chapter 5  Command Basics 
DMC-1700/1800 
Example 
The command  ST XYZS would be  
A1 00 01 07 
where   A1 is the command number for ST 
 
00 specifies 0 data fields 
 
01 specifies stop the coordinated axes S 
 
07 specifies stop X (bit 0), Y (bit 1) and Z (bit 2)  2
0
+2
1
+2
3
 =7 
Binary command table 
COMMAND NO. 
COMMAND  NO. 
COMMAND 
NO. 
 
 
 
 
 
 
reserved 80  reserved  ab 
reserved 
d6 
KP 81 
reserved 
ac 
reserved 
d7 
KI 82 
reserved 
ad  RP 
d8 
KD 83 
reserved 
ae 
TP 
d9 
DV 84 
reserved 
af 
TE 
da 
AF 
85      
LM 
b0 
TD 
db 
KF 86 
LI 
b1 
TV 
dc 
PL 87 
VP  b2 
RL 
dd 
ER 88 
CR  b3 
TT 
de 
IL 89 
TN  b4  TS 
df 
TL 8a 
LE, 
VE 
b5 
TI 
e0 
MT 8b 
VT 
b6 
SC 
e1 
CE 8c 
VA  b7 
reserved 
e2 
OE 
8d 
VD 
b8       
reserved 
e3 
FL 8e 
VS  b9 
reserved 
e4 
BL 8f 
VR  ba 
TM 
e5 
AC 
90      
reserved 
bb 
CN 
e6 
DC 91 
reserved 
bc 
LZ 
e7 
SP 92 
CM  bd  OP 
e8 
IT 93 
CD  be  OB  e9 
FA 94 
DT  bf 
SB 
ea 
FV 95 
ET  c0 
CB 
eb 
GR 96 
EM  c1 
ec 
DP 97 
EP  c2 
EI 
ed 
DE 
98      
EG 
c3 
AL 
ee 
OF 99 
EB  c4 
reserved 
ef 
GM 9a 
EQ 
c5 
reserved f0 
reserved 9b  EC 
c6 
reserved 
f1 
reserved 9c  reserved  c7 
reserved 
f2 
reserved 
9d 
AM 
c8      
reserved 
f3 
reserved 9e  MC 
c9 
reserved 
f4 
reserved 9f  TW 
ca 
reserved 
f5 
BG 
a0      
MF 
cb 
reserved 
f6 
ST a1 
MR  cc 
reserved 
f7 
AB a2 
AD  cd 
reserved 
f8 
HM a3 
AP 
ce 
reserved f9 
FE a4 
AR  cf 
reserved 
fa 
FI a5 
AS  d0  reserved 
fb 
PA a6 
AI 
d1 
reserved 
fc