Direct Wire Method – U.S. Only
Direct wire cable must match power supply (4-wire or 3-wire)  
and be:
n
   Flexible armored cable or nonmetallic sheathed copper cable 
(with ground wire), covered with flexible metallic conduit.  
All current-carrying wires must be insulated.
n
   10-gauge solid copper wire (do not use aluminum).
n
   At least 5 ft. (1.52 m) long.
1.   Disconnect  power.
2.   Remove hold-down screw and terminal block cover.
3.    Install 3/4" conduit connector into the hole below the terminal 
block opening. Connect flexible metallic conduit and tighten 
connector screw. Install direct wire cable through the flexible 
metallic conduit.
4.   Complete installation following instructions for your type of 
electrical connection:
• Four-wire (recommended method)
• Three-wire (if four-wire is not available)
C
D
B
A
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw
A
To  
disconnect 
box
B
D
5" (127 mm)
3
1
2
" (89 mm) 
1" (25 mm) 
of wires 
stripped of 
insulation
C
Strip 5" (127 mm) of outer covering 
from end of cable. Leave green or 
bare ground wire at 5" (127 mm). 
Cut 1
1
2
" (38 mm) from 3 remaining 
wires. Strip insulation back 1"  
(25 mm).
Shape 
ends of 
wires into  
a hook.
C
B
A
E
D
F
5.   Remove the center terminal block screw.
6.   Remove the appliance neutral ground 
wire from the external ground conductor 
screw. Fasten under center terminal 
block screw.
7.   Connect the ground wire (green or bare) 
of the direct wire cable to the external 
ground conductor screw. Tighten screw.
8.   Place the hooked end of the neutral wire 
(white or center) of the direct wire cable 
under the center screw of the terminal 
block (hook facing right). Squeeze hook 
end together. Tighten screw.
9.   Place the hooked ends of the other 
direct wire cable wires under the outer 
terminal block screws (hook facing right). 
Squeeze hooked ends together. Tighten 
screws.
10.  Insert tab of the terminal block cover into 
slot of the dryer rear panel. Secure cover 
with hold-down screw.
Direct Wire,  
Four-wire electrical connection:
A. 3/4" (19 mm) conduit connector
B. Neutral (white or center)
C. Ground wire (green or bare)
D.  10-gauge, 3 wire with ground wire  
in flexible metallic conduit
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Neutral (center wire)
F. Green or bare ground wire
B
C
A
A. Conduit connector 
B. Dryer cabinet
C. Connector screw