User Manual (BBS2600JF)Table of Contents1. Introduction1Section Outline1Server Board Use Disclaimer22. Server Board Overview3Figure 1. Intel® Server Board S2600JF (InfiniBand* SKU)3Table 1. Intel® Server Board S2600JF Feature Set3Server Board Connector and Component Layout5Figure 2. Intel® Server Board S2600JF components52.1.1 Board Rear Connector Placement6Figure 3. Rear Panel Connector Placement62.1.2 Server Board Mechanical Drawings7Figure 4. Baseboard and Mounting holes73. Product Architecture Overview8High Level Product Features8Table 2. Intel® Server Board S2600JF Features8Figure 5. Intel® Server Board S2600JF Functional Block Diagram9Processor Support103.2.1 Processor Socket Assembly10Figure 6. Processor Socket Assembly103.2.2 Processor Population Rules11Figure 7. Processor Socket ILM Variations11Table 3. Mixed Processor Configurations12Processor Function Overview133.3.1 Intel® QuickPath Interconnect143.3.2 Integrated Memory Controller (IMC) and Memory Subsystem14Figure 8. Processor with IMC Functional Block Diagram14Table 4. UDIMM Support Guidelines16Table 5. RDIMM Support Guidelines16Table 6. LRDIMM Support Guidelines16Figure 9. Intel® Server Board S2600JF family DIMM Slot Layout17Table 7. Intel® Server Board S2600JF DIMM Nomenclature173.3.3 Processor Intergrated I/O Module (I/O)19Figure 10. General Functional Block Diagram of Processor I/O Sub-system20Figure 11.PCI Express* Lane distribution scheme21Figure 12. PCIe Riser for Slot 122Table 8. CPU1 and CPU2 PCIe Connectivity22Intel® C600-A/B PCH Functional Overview23Figure 13. PCIe Riser for Slot 2233.4.1 PCI Express*24Figure 14. Intel® C600-A/B PCH connection243.4.2 Non-Transparent Bridge253.4.3 Universal Serial Bus (USB)253.4.4 Serial Attached SCSI (SAS) and Serial ATA (SATA) Controller25Table 9. Intel® Server Board S2600JF SATA/SAS port26Table 10. Intel® RAID C600 Storage Upgrade Key Options for S2600JF263.4.5 PCI Interface273.4.6 Low Pin Count (LPC) Interface273.4.7 Digital Media Interface (DMI)273.4.8 Serials Peripheral Interface (SPI)273.4.9 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)273.4.10 Advanced Programmable Interrupt Controller (APIC)283.4.11 Real Time Clock (RTC)283.4.12 GPIO283.4.13 Enhanced Power Management283.4.14 Fan Speed Control283.4.15 Intel® Virtualization Technology for Direct I/O (Intel® VT-d)283.4.16 KVM/Serial Over LAN (SOL) Function293.4.17 IDE-R Function293.4.18 Manageability293.4.19 System Management Bus (SMBus 2.0*)303.4.20 Network Interface Controller (NIC)30Figure 15. 1GbE NIC port LED31Table 11. NIC Status LED31InfiniBand* Controller323.5.1 Device Interfaces32Figure 16. ConnectX®-3 function block diagram323.5.2 Quad Small Form-factor Pluggable (QSFP) connector33Figure 17. Connection between ConnectX®-3 and QSFP33Table 12. Network port configuration33Integrated Baseboard Management Controller Overview34Figure 18. Integrated BMC implementation overview34Figure 19. Integrated BMC Functional Block Diagram343.6.1 Super I/O Controller353.6.2 Graphics Controller and Video Support36Table 13. Supported Video Modes363.6.3 Remote KVM37Table 14. Dual Video Option374. Platform Management Functional Overview38Baseboard Management Controller (BMC) Firmware Feature Support384.1.1 IPMI 2.0 Features384.1.2 Non IPMI Features394.1.3 New Manageability Features40Advanced Configuration and Power Interface (ACPI)42Platform Management SMBus* and I2C Implementation42Table 15. ACPI Power States42BMC Internal Timestamp Clock43Sensor Monitoring43Messaging Interfaces434.6.1 Channel Management434.6.2 User Model44Table 16. Standard Channel Assignments44Table 17. Default User Values444.6.3 Sessions45Table 18. Channel/Media-specific minimum number of sessions454.6.4 BMC LAN Channels464.6.5 IPV6 Support47System Event Log (SEL)484.7.1 Servicing Events494.7.2 SEL Entry Deletion494.7.3 SEL Erasure494.7.4 SEL Extension Capabilities49Sensor Data Record (SDR) Repository49Field Replaceable Unit (FRU) Inventory Device50Diagnostics and Beep Code Generation50Diagnostics Interrupt (NMI)50Table 19. BMC Beep Codes50BMC Basic and Advanced Management Features51Table 20. NMI Signal Generation and Event Logging51Table 21. Basic and Advanced Management Features514.12.1 Enabling Advanced Manageability Features52Table 22. Management features and Benefits524.12.2 Media Redirection544.12.3 Embedded Web server554.12.4 Data Center Management Interface (DCMI)564.12.5 Local Directory Authentication Protocol (LDAP)574.12.6 Platform/Chassis Management574.12.7 Thermal Control57Table 23. Fan Profile Mapping584.12.8 Node Power On/Off Control59Intel® Intelligent Power Node Manager594.13.1 Overview594.13.2 Features59Management Engine (ME)604.14.1 Overview604.14.2 BMC – Management Engine (ME) Distributed Model604.14.3 ME System Management Bus (SMBus*) Interface614.14.4 BMC - Management Engine Interaction61Figure 20. Management Engine Distribution Model614.14.5 ME Power and Firmware Startup624.14.6 SmaRT/CLST62Other Platform Management634.15.1 Wake On LAN (WOL)634.15.2 PCI Express* Power management634.15.3 PMBus*634.15.4 Node Power Policies635. BIOS Setup Interface64HotKeys Supported During POST64POST Logo/Diagnostic Screen64Table 24. POST HotKeys Recognized64BIOS Boot Pop-up Menu65BIOS Setup Utility655.4.1 BIOS Setup Operation65Table 25. BIOS Setup Page Layout66Table 26. BIOS Setup: Keyboard Command Bar675.4.2 BIOS Setup Utility Screens68Table 27. Screen Map70Figure 21. Main Screen71Table 28. Setup Utility – Main Screen Fields71Figure 22. Advanced Screen73Table 29. Setup Utility – Advanced Screen Display Fields73Figure 23. Processor Configuration Screen74Table 30. Setup Utility – Processor Configuration Screen Fields74Figure 24. Power and Performance Configuration Screen78Table 31. Setup Utility – Power and Performance Configuration Screen Fields78Table 32. Power/Performance Profiles78Figure 25. Memory Configuration Screen80Table 33. Setup Utility – Memory Configuration Screen Fields81Figure 26. Memory RAS and Performance Configuration Screen82Table 34. Setup Utility – Memory RAS and Performance Configuration Fields82Figure 27. Mass Storage Controller Configuration Screen84Table 35. Setup Utilities – Mass Storage Controller Configuration Fields84Figure 28. PCI Configuration Screen85Table 36. Setup Utility – PCI Configuration Screen Fields86Figure 29. NIC Configuration Screen88Table 37. Setup Utility – NIC Configuration Screen Fields88Figure 30. Serial Port Configuration Screen91Table 38. Setup Utility – Serial Ports Configuration Screen Fields91Figure 31. USB Configuration Screen92Table 39. Setup Utility – USB Controller Configuration Screen Fields92Figure 32. System Acoustic and Performance Configuration93Table 40. Setup Utility – System Acoustic and Performance Configuration Screen Fields94Figure 33. Security Screen96Table 41. Setup Utility – Security Configuration Screen Fields96Figure 34. Server Management Screen98Table 42. Setup Utility – Server Management Configuration Screen Fields98Figure 35. Console Redirection Screen100Table 43. Setup Utility – Console Redirection Configuration Fields100Figure 36. System Information Screen102Table 44. Setup Utility – Server Management System Information Fields102Figure 37. BMC LAN Configuration Screen104Table 45. Setup Utility — BMC configuration Screen Fields104Figure 38. Boot Options Screen106Table 46. Setup Utility – Boot Options Screen Fields107Figure 39. Hard Disk Order Screen108Table 47. Setup Utility – Hard Disk Order Fields108Figure 40. Network Device Order Screen109Figure 41. Delete EFI Boot Option Screen109Table 48. Setup Utility – Network Device Order Fields109Table 49. Setup Utility – Delete Boot Option Fields109Figure 42. Boot Manager Screen110Table 50. Setup Utility – Boot Manager Screen Fields110Figure 43. Error Manager Screen111Figure 44. Exit Screen111Table 51. Setup Utility – Error Manager Screen Fields111Loading BIOS Defaults112Table 52. Setup Utility – Exit Screen Fields1126. Configuration Jumpers113Figure 45. Jumper Blocks (J6B1, J1E2, J1E3, J1E1, J1D5)1136.1.1 Force Integrated BMC Update (J6B1)114Table 53. Server Board Jumpers (J6B1, J1E2, J1E3, J1E1, J1D5)114Table 54. Force Integrated BMC Update Jumper1146.1.2 Force ME Update (J1E2)1156.1.3 Password Clear (J1E3)115Table 55. Force ME Update Jumper1156.1.4 BIOS Recovery Mode (J1E1)116Table 56. Password Clear Jumper116Table 57. BIOS Recovery Mode Jumper1166.1.5 Reset BIOS Settings (J1D5)117Table 58. Reset BIOS Jumper1177. Connector/Header Locations and Pin-out119Power Connectors119System Management Headers1197.2.1 Intel® Remote Management Module 4 (Intel® RMM4 Lite) Connector1197.2.2 IPMB Header119Bridge Board Connector119Table 59. Main Power Supply Connector 6-pin 2x3 Connector (J4K1 and J3K1)119Table 60. Intel® RMM4 Lite Connector Pin-out (J1A2)119Table 61. IPMB Header 4-pin (J2D2)119Table 62. Bridge Board Connector (J1D1)1207.3.1 Power Button1217.3.2 Reset Button1217.3.3 Chassis Identify Button1217.3.4 Power LED121Table 63. Power LED Indicator States1217.3.5 System Status LED122Figure 46. System Status LED (A) and ID LED (B)122Table 64. System Status LED1227.3.6 Chassis ID LED124I/O Connectors1247.4.1 PCI Express* Connectors124Table 65. Chassis ID LED Indicator States124Table 66. PCI Express* x16 Riser Slot 1 Connector (J6A1)124Table 67. PCI Express* x16 Riser Slot 2 Connector (J1A3)126Table 68. PCI Express* x16 Riser Slot 3 Connector (J1H1)1287.4.2 VGA Connector130Table 69. PCI Express* Riser ID Assignment130Table 70. PCI Express* Clock Source by Slot130Table 71. VGA External Video Connector (J4A1)130NIC Connectors131SATA Connectors131Table 72. RJ-45 10/100/1000 NIC Connector Pin-out (JA6A1, JA5A1)131Hard Drive Activity (Input) LED Header132Storage Upgrade Key Connector132Serial Port Connectors132Table 73. SATA Connector132Table 74. SATA HDD Activity (Input) LED Header (J6C5)132Table 75. Storage Upgrade Key Connector (J6C4)132Table 76. Internal 9-pin Serial A (COM1) (J6A2)132USB Connectors133QSFP for InfiniBand*133Table 77. External USB port Connector (J3A1)133Table 78. Internal USB Connector (J2D1)133Table 79. QSFP Pin Definition133Fan Headers134Chassis Intrusion134Table 80. Baseboard Fan Connector (J1K2)134Table 81. Chassis Intrusion Header (J6C1)1348. Intel Light-Guided Diagnostics135Front Panel Support135System ID LED135System Status LED135Network Link/Activity LED135Table 82. Network link/activity LED135Dedicated InfiniBand* Link/Activity LED136POST Code Diagnostic LEDs136Figure 47. Rear Panel Diagnostic LEDs (Block A)136Table 83. InfiniBand* link/activity LED1369. Environmental Limits Specification137System Level Environmental Considerations137Table 84. Server Board Design Specifications137Set Throttling Mode138Altitude138Set Fan Profile138Fan PWM Offset138Quiet Fan Idle Mode138Thermal Sensor Input for Fan Speed Control139Processor Thermal Design Power (TDP) Support14010. Power Supply Specification Guidelines141Power Supply DC Output Connector141Power Supply DC Output Specification14110.2.1 Output Power/Currents14110.2.2 Standby Output14110.2.3 Voltage Regulation141Table 85. Power Supply DC Power Input Connector Pin-out (See Table 60)141Table 86. Minimum Load Ratings14110.2.4 Dynamic Loading14210.2.5 Capacitive Loading14210.2.6 Grounding14210.2.7 Closed loop stability14210.2.8 Residual Voltage Immunity in Standby mode142Table 87. Voltage Regulation Limits142Table 88. Transient Load Requirements142Table 89. Capacitive Loading Conditions14210.2.9 Common Mode Noise14310.2.10 Soft Starting14310.2.11 Zero Load Stability Requirements14310.2.12 Hot Swap Requirements14310.2.13 Forced Load Sharing14310.2.14 Ripple/Noise14310.2.15 Timing Requirement143Table 90. Ripples and Noise143Table 91. Timing Requirements144Figure 48. Turn On/Off Timing (Power Supply Signals)145Appendix A: Integration and Usage Tips146Appendix B: Integrated BMC Sensor Tables147Table 92. BMC Sensor Table149Appendix C: BIOS Sensors and SEL Data162Table 93. BIOS Sensor and SEL Data162Appendix D: POST Code LED Decoder169Figure 49. Diagnostic LED Placement Diagram169Table 94. POST Progress Code LED Example170Table 95. Diagnostic LED POST Code Decoder170Appendix E: Video POST Code Errors174Table 96. POST Error Messages and Handling174Glossary178Table 97. Glossary178Reference Documents181Size: 3.7 MBPages: 194Language: EnglishOpen manual