Manual Do Utilizadoríndice analíticoTitle Page1Safety and Regulatory Information3In This Guide...10Contents13Introducing the Agilent 85225F Performance Modeling System17Performance Modeling System Configuration Overview18RF and DC Measurement System Configuration19Figure 1 System Block Diagram19The RF Subsystem20The DC Subsystem20The Bias Networks21Component Integration22Figure 2 System Components23Table 3 Front Panel System Connections, with Agilent 4156C24Figure 3 Front Panel Connections with Agilent 4156C25Table 4 Front Panel System Connections, with Agilent E5260A or E5270B26Figure 4 Front Panel Wiring Diagram with Agilent E5260A or E5270B27Table 5 Rear Panel System Connections with Agilent 4156C28Figure 5 Rear Panel Wiring Diagram with Agilent 4156C29Table 6 Rear Panel System Connections with Agilent E5260A or E5270B30Figure 6 Rear Panel Wiring with Agilent E5260A or E5270B31Figure 7 DC/RF Cabling Diagram - DC and RF Configuration32CV, RF, and DC Measurement System Configuration33Figure 8 System Block Diagram33The CV Subsystem34Component Integration34Figure 9 System Components35Table 7 Front Panel System Connections36Figure 10 Front Panel Wiring Diagram37Table 8 Rear Panel System Connections38Figure 11 Rear Panel Wiring Diagram39Figure 12 DC/RF Cabling Diagram - DC and RF Configuration40Figure 13 DC/RF Cabling Diagram - Parametric Configuration41The Low Leakage Switch Mainframe42Table 9 Rear Panel Connections, including Low Leakage Switch Mainframe42Figure 14 Rear Panel Wiring Diagram including Low Leakage Switch Mainframe43Figure 15 DC/RF Cabling Diagram - Parametric Configuration with Low Leakage Switch Mainframe441/f Noise, CV, RF, and DC Measurement System Configuration45Figure 16 System Block Diagram46Figure 17 1/f Noise Measurement Block Diagram47Component Integration48Figure 18 System Components49Table 10 Front Panel System Connections50Figure 19 Front Panel Wiring Diagram51Table 11 Rear Panel System Connections52Figure 20 Rear Panel Wiring Diagram53Figure 21 DC/RF Cabling Diagram - DC and RF Configuration54Figure 22 DC/RF Cabling Diagram - Parametric Configuration55Instrument Control Interface56Table 12 GPIB Addresses56The LAN/GPIB Gateway57Figure 23 Rear Panel Wiring Diagram for LAN/GPIB Gateway58The System Controller59Table 13 Personal Computer Requirements59Table 14 UNIX Workstation Requirements59The Rack Cabinet60Performance Characteristics and Specifications61Table 15 Supplemental System Characteristics61Interference Standards61Performance Modeling System Performance Specifications61RF Subsystem Performance Specifications62DC Subsystem Specifications62Bias Network Characteristics62Installing the System63To prepare the installation site64Table 16 Environmental Requirements64Table 17 Electrical Requirements64To receive the system65To unpack the shipment crate containing the rack cabinet66To verify the shipment68Table 18 Replaceable Parts69To install the work surface74To ensure your safety while using the system76Precautions for Performing Floating-Ground Measurements78To perform floating-ground measurements78Precautions for Avoiding Electrostatic Discharge79To connect the bias networks80Agilent 4156C Systems80Agilent 4156C Systems with Agilent 41501B Expander Box82Agilent E5260A/70B Systems84To switch on power to the system87To configure the LAN/GPIB gateway for functional verification89Verifying System Functionality91To choose a verification process92Understanding the System Functional Verification Test94Required Tools94Performing the System Functional Verification Test95If you encounter a problem101Servicing the System103To troubleshoot the system104To remove or replace a system component105To order replacement parts106To receive additional assistance107Table 19 Contacting Agilent Technologies107To package the system for transport108Enhancing Measurement Accuracy111To enhance measurement accuracy112Understanding System Measurement Calibration114Required Tools114Performing a Coaxial System Measurement Calibration115If you encounter a problem116Periodic System Component Calibration117DC Subsystem Functional Verification Test119Understanding the DC Subsystem Functional Verification Test120Required Tools120Performing the DC Subsystem Functional Verification Test121If you encounter a problem121If you encounter a problem122RF Subsystem Functional Verification Test123Understanding the RF Subsystem Functional Verification Test124Required Tools124Performing the RF Subsystem Functional Verification Test125If you encounter a problem127CV Subsystem Functional Verification Test129Understanding the CV Subsystem Functional Verification Test130Required Tools130Performing the CV Subsystem Functional Verification Test131If you encounter a problem1321/f Noise Subsystem Functional Verification Test133Understanding the 1/f Noise Subsystem Functional Verification Test134Required Tools134Performing the 1/f Noise Subsystem Functional Verification Test135If you encounter a problem136Understanding the Bias Networks137Features138Characteristics139Table 20 11612V Option K11/K21 Bias Network Characteristics139Operation140Figure 24 Bias Network Schematic140Network Analyzer Performance Specification Summary141Network Analyzer System Performance142Maximum Output Power142Dynamic Range142Measurement Port Characteristics143Measurement Uncertainty143Index145Tamanho: 2 MBPáginas: 148Language: EnglishAbrir o manual