Manual Do Utilizadoríndice analíticoSECTION 1: Product Description121.1: Features and Options121.2: Specifications131.2.1: Current Availability151.3: Controls and Indicators161.4: Circuits171.5: Digital Alarm Communicator/Transmitter171.6: Components181.6.1: Intelligent Addressable Detectors: Newer Series181.6.2: Intelligent Addressable Modules: Newer Series191.6.3: 300 Series Intelligent Addressable Devices191.6.4: Addressable Device Accessories191.7: Optional Modules201.8: Accessories201.8.1: PK-CD Programming Utility201.8.2: Dress Panel201.8.3: Battery Box211.8.4: Battery Charger211.8.4.1 CHG-75 Battery Charger211.8.4.2 CHG-120F Battery Charger211.8.5: Annunciators221.9: Getting Started231.10: Telephone Requirements and Warnings241.10.1: Telephone Circuitry241.10.2: Digital Communicator241.10.3: Telephone Company Rights and Warnings251.10.4: For Canadian Applications26SECTION 2: Installation272.1: Mounting Backbox272.2: Mounting Transformer282.3: Power312.3.1: AC Power and Earth Ground Connection312.3.2: Battery Power312.3.3: Special Application DC Power Output Connection312.4: Relays322.5: Notification Appliance Circuits322.5.1: Configuring NACs332.5.2: Style Y (Class B) NAC Wiring332.5.3: Style Z (Class A) NAC Wiring342.6: Remote Synchronization Output342.7: UL Power-limited Wiring Requirements352.8: Digital Communicator362.9: Optional Module Installation372.9.1: 4XTMF Transmitter Module Installation382.9.2: Printer/PC402.9.3: Digital Communicator and Annunciators412.9.3.1 ACM-8RF Relay Control Module412.9.3.2 ACS and AFM Series Annunciators41SECTION 3: Programming423.1: Programming Data Entry423.2: User Programming433.3: Initial Power-up443.4: Programming Screens Description443.5: Programming and Passwords443.6: Master Programming Level463.6.1: Autoprogram473.6.2: Point Program483.6.2.1 Detector Programming483.6.2.1.1 Add Detector483.6.2.1.2 Delete Detector493.6.2.1.3 Edit Detector493.6.2.2 Module Programming583.6.2.2.1 Add Module583.6.2.2.2 Delete Module593.6.2.2.3 Edit Module Screen for Monitor Module593.6.2.2.4 Edit Module Screen for Control Modules683.6.3: Zone Setup753.6.3.1 Enable753.6.3.2 Disable763.6.3.3 Zone 97, 98 and 99763.6.3.4 Zones Installed773.6.3.5 Zones Enabled773.6.3.6 Zones Disabled773.6.3.7 Zone Type783.6.3.8 Zones Available793.6.4: Loop Setup793.6.4.1 Style793.6.4.2 Loop Protocol793.6.5: System Setup803.6.5.1 Trouble Reminder813.6.5.2 Banner813.6.5.3 Time-Date823.6.5.3.1 Time823.6.5.3.2 Date833.6.5.3.3 Clock Format833.6.5.3.4 Daylight Savings Time833.6.5.4 Timers843.6.5.4.1 PAS (Positive Alarm Sequence) Delay843.6.5.4.2 Pre-signal Delay853.6.5.4.3 Waterflow Delay853.6.5.4.4 AC Loss Delay863.6.5.5 NAC (Notification Appliance Circuit)863.6.5.5.1 Enabled873.6.5.5.2 Type883.6.5.5.3 Silenceable883.6.5.5.4 Auto Silence893.6.5.5.5 Coding (only for NACs not programmed as Sync Strobe Type)893.6.5.5.6 Zone913.6.5.5.7 Silence Inhibited913.6.5.5.8 Sync Type913.6.5.6 Relays923.6.5.7 Canadian Option933.6.5.8 Waterflow Silenceable933.6.6: Verify Loop933.6.7: History943.6.7.1 View Events943.6.7.2 Erase History943.6.8: Walktest953.6.9: Option Modules963.6.9.1 Annunciators/UDACT963.6.9.2 Onboard DACT973.6.9.2.1 Onboard DACT Enable973.6.9.2.2 Primary Phone983.6.9.2.3 Secondary Phone983.6.9.2.4 Service Terminal993.6.9.2.5 Central Station1013.6.9.2.6 Trouble Call Limit (Dialer Runaway Prevention)1023.6.9.2.7 Manual Dial Mode1143.6.9.3 Printer/PC1153.6.10: Password Change1163.6.11: Clear Program1173.6.12: Program Check1183.7: Maintenance Programming Level1203.7.1: Disable Point1213.7.2: History1223.7.3: Program Check1233.7.4: Walktest1243.7.5: System1243.7.6: Zone Setup126SECTION 4: Operating Instructions1284.1: Panel Control Buttons1284.1.1: Acknowledge/Step1284.1.2: Alarm Silence1284.1.3: Drill/Hold 2 Sec1284.1.4: Reset1284.2: LED Indicators1294.3: Normal Operation1304.4: Trouble Operation1304.5: Alarm Operation1324.6: Supervisory Operation1334.7: Process Monitor Operation1344.8: Hazard/Tornado Condition Operation1344.9: Medical Alert Condition Operation1344.10: NAC Operation1344.11: Programmed Zone Operation1354.12: Disable/Enable Operation1354.13: Waterflow Circuits Operation1354.14: Detector Functions1354.15: Time Functions: Real-Time Clock1354.16: Synchronized NAC Operation1364.17: Coded Operation1364.18: Presignal1364.19: Positive Alarm Sequence1374.20: Special System Timers1384.20.1: Silence Inhibit Timer1384.20.2: Autosilence Timer1384.20.3: Trouble Reminder1384.20.4: Waterflow Retard Timer1384.20.5: Alarm Verification (None or One Minute)1394.21: Walktest1394.22: Read Status1404.22.1: System Point1414.22.2: Zones1424.22.3: Power1434.22.4: Trouble Reminder1444.22.5: Timers1444.22.6: NAC1454.22.7: Relays1454.22.8: Program Check1464.22.9: History1464.22.10: Annunciators1474.22.11: Phone Line1474.22.12: Central Station1484.22.13: Service Terminal1494.22.14: Printer/PC1494.22.15: Print1504.22.16: Time-Date152SECTION 5: Central Station Communications1535.1: Transmittal Priorities156SECTION 6: Remote Site Upload/Download1586.1: Downloading Program1586.1.1: Security Features1596.2: Downloading Initiated at a Service Terminal1616.3: Uploading Initiated at a Service Terminal162SECTION 7: Power Supply Calculations1637.1: Overview1637.2: Calculating the AC Branch Circuit1637.3: Calculating the System Current Draw1647.3.1: Overview1647.3.2: How to Use Table 7.3 on page 165 to Calculate System Current Draw1647.4: Calculating the Battery Size1667.4.1: NFPA Battery Requirements1667.4.2: Selecting and Locating Batteries166APPENDIX A: Software Zones167A.1: Correlations167APPENDIX B: Default Programming173APPENDIX C: NFPA Standard-Specific Requirements174APPENDIX D: Wire Requirements178APPENDIX E: HVAC Control179E.1: Control Module Operation179E.1.1: HVAC SHUTDN179E.2: Monitor Module Operation179E.2.1: HVAC RESTART179E.2.2: HVAC OVRRIDE180Tamanho: 2 MBPáginas: 188Language: EnglishAbrir o manual
Manual Do Utilizadoríndice analíticoSECTION 1: Product Description121.1: Features and Options121.2: Specifications131.2.1: Current Availability151.3: Controls and Indicators161.4: Circuits171.5: Digital Alarm Communicator/Transmitter171.6: Components181.6.1: Intelligent Addressable Detectors: Newer Series181.6.2: Intelligent Addressable Modules: Newer Series191.6.3: 300 Series Intelligent Addressable Devices191.6.4: Addressable Device Accessories191.7: Optional Modules201.8: Accessories201.8.1: PK-CD Programming Utility201.8.2: Dress Panel201.8.3: Battery Box211.8.4: Battery Charger211.8.4.1 CHG-75 Battery Charger211.8.4.2 CHG-120F Battery Charger211.8.5: Annunciators221.9: Getting Started231.10: Telephone Requirements and Warnings241.10.1: Telephone Circuitry241.10.2: Digital Communicator241.10.3: Telephone Company Rights and Warnings251.10.4: For Canadian Applications26SECTION 2: Installation272.1: Mounting Backbox272.2: Mounting Transformer282.3: Power312.3.1: AC Power and Earth Ground Connection312.3.2: Battery Power312.3.3: Special Application DC Power Output Connection312.4: Relays322.5: Notification Appliance Circuits322.5.1: Configuring NACs332.5.2: Style Y (Class B) NAC Wiring332.5.3: Style Z (Class A) NAC Wiring342.6: Remote Synchronization Output342.7: UL Power-limited Wiring Requirements352.8: Digital Communicator362.9: Optional Module Installation372.9.1: 4XTMF Transmitter Module Installation382.9.2: Printer/PC402.9.3: Digital Communicator and Annunciators412.9.3.1 ACM-8RF Relay Control Module412.9.3.2 ACS and AFM Series Annunciators41SECTION 3: Programming423.1: Programming Data Entry423.2: User Programming433.3: Initial Power-up443.4: Programming Screens Description443.5: Programming and Passwords443.6: Master Programming Level463.6.1: Autoprogram473.6.2: Point Program483.6.2.1 Detector Programming483.6.2.1.1 Add Detector483.6.2.1.2 Delete Detector493.6.2.1.3 Edit Detector493.6.2.2 Module Programming583.6.2.2.1 Add Module583.6.2.2.2 Delete Module593.6.2.2.3 Edit Module Screen for Monitor Module593.6.2.2.4 Edit Module Screen for Control Modules683.6.3: Zone Setup753.6.3.1 Enable753.6.3.2 Disable763.6.3.3 Zone 97, 98 and 99763.6.3.4 Zones Installed773.6.3.5 Zones Enabled773.6.3.6 Zones Disabled773.6.3.7 Zone Type783.6.3.8 Zones Available793.6.4: Loop Setup793.6.4.1 Style793.6.4.2 Loop Protocol793.6.5: System Setup803.6.5.1 Trouble Reminder813.6.5.2 Banner813.6.5.3 Time-Date823.6.5.3.1 Time823.6.5.3.2 Date833.6.5.3.3 Clock Format833.6.5.3.4 Daylight Savings Time833.6.5.4 Timers843.6.5.4.1 PAS (Positive Alarm Sequence) Delay843.6.5.4.2 Pre-signal Delay853.6.5.4.3 Waterflow Delay853.6.5.4.4 AC Loss Delay863.6.5.5 NAC (Notification Appliance Circuit)863.6.5.5.1 Enabled873.6.5.5.2 Type883.6.5.5.3 Silenceable883.6.5.5.4 Auto Silence893.6.5.5.5 Coding (only for NACs not programmed as Sync Strobe Type)893.6.5.5.6 Zone913.6.5.5.7 Silence Inhibited913.6.5.5.8 Sync Type913.6.5.6 Relays923.6.5.7 Canadian Option933.6.5.8 Waterflow Silenceable933.6.6: Verify Loop933.6.7: History943.6.7.1 View Events943.6.7.2 Erase History943.6.8: Walktest953.6.9: Option Modules963.6.9.1 Annunciators/UDACT963.6.9.2 Onboard DACT973.6.9.2.1 Onboard DACT Enable973.6.9.2.2 Primary Phone983.6.9.2.3 Secondary Phone983.6.9.2.4 Service Terminal993.6.9.2.5 Central Station1013.6.9.2.6 Trouble Call Limit (Dialer Runaway Prevention)1023.6.9.2.7 Manual Dial Mode1143.6.9.3 Printer/PC1153.6.10: Password Change1163.6.11: Clear Program1173.6.12: Program Check1183.7: Maintenance Programming Level1203.7.1: Disable Point1213.7.2: History1223.7.3: Program Check1233.7.4: Walktest1243.7.5: System1243.7.6: Zone Setup126SECTION 4: Operating Instructions1284.1: Panel Control Buttons1284.1.1: Acknowledge/Step1284.1.2: Alarm Silence1284.1.3: Drill/Hold 2 Sec1284.1.4: Reset1284.2: LED Indicators1294.3: Normal Operation1304.4: Trouble Operation1304.5: Alarm Operation1324.6: Supervisory Operation1334.7: Process Monitor Operation1344.8: Hazard/Tornado Condition Operation1344.9: Medical Alert Condition Operation1344.10: NAC Operation1344.11: Programmed Zone Operation1354.12: Disable/Enable Operation1354.13: Waterflow Circuits Operation1354.14: Detector Functions1354.15: Time Functions: Real-Time Clock1354.16: Synchronized NAC Operation1364.17: Coded Operation1364.18: Presignal1364.19: Positive Alarm Sequence1374.20: Special System Timers1384.20.1: Silence Inhibit Timer1384.20.2: Autosilence Timer1384.20.3: Trouble Reminder1384.20.4: Waterflow Retard Timer1384.20.5: Alarm Verification (None or One Minute)1394.21: Walktest1394.22: Read Status1404.22.1: System Point1414.22.2: Zones1424.22.3: Power1434.22.4: Trouble Reminder1444.22.5: Timers1444.22.6: NAC1454.22.7: Relays1454.22.8: Program Check1464.22.9: History1464.22.10: Annunciators1474.22.11: Phone Line1474.22.12: Central Station1484.22.13: Service Terminal1494.22.14: Printer/PC1494.22.15: Print1504.22.16: Time-Date152SECTION 5: Central Station Communications1535.1: Transmittal Priorities156SECTION 6: Remote Site Upload/Download1586.1: Downloading Program1586.1.1: Security Features1596.2: Downloading Initiated at a Service Terminal1616.3: Uploading Initiated at a Service Terminal162SECTION 7: Power Supply Calculations1637.1: Overview1637.2: Calculating the AC Branch Circuit1637.3: Calculating the System Current Draw1647.3.1: Overview1647.3.2: How to Use Table 7.3 on page 165 to Calculate System Current Draw1647.4: Calculating the Battery Size1667.4.1: NFPA Battery Requirements1667.4.2: Selecting and Locating Batteries166APPENDIX A: Software Zones167A.1: Correlations167APPENDIX B: Default Programming173APPENDIX C: NFPA Standard-Specific Requirements174APPENDIX D: Wire Requirements178APPENDIX E: HVAC Control179E.1: Control Module Operation179E.1.1: HVAC SHUTDN179E.2: Monitor Module Operation179E.2.1: HVAC RESTART179E.2.2: HVAC OVRRIDE180Tamanho: 2 MBPáginas: 188Language: EnglishAbrir o manual